Plant Care
- • Climate Control & VPD16
- • Disease & Pest Management14
- • Nutrient Solutions & EC34
- • Plant Health Monitoring7
10 parameters · live recalculation on every change
The planned footprint, pulled down by what the array covers — the running total lands on the still-dark area.
Running total after each term — the final net matches the headline reading in the result card, kept in sync live.
This is a deterministic model: the same inputs always produce the same outputs, calculated entirely in your browser with nothing sent to any server. It is a planning aid — not a quote, not a dosing instruction, and not a yield forecast. Treat every line as a working estimate and validate it against your own prices and measurements.
It models one system: The Pro-level coverage and spectrum blueprint for a grow area. Enter the footprint, fixture form-factor, photon count, mounting height and dim curve and the engine returns the average canopy PPFD scaled by the inverse-square law, the uniformity grade that separates a bar board from a quantum board, the delivered daily light integral with the sunrise ramp compensated, the inter-canopy light that reaches the lower third, the UV-A and UV-B contribution as a share of the run, and the driver waste-heat and DC-drop load your wiring and cooling must carry.
The engine computes 10 outputs from your 10 inputs. The headline number is Avg Canopy PPFD (µmol/m²/s), alongside Uniformity, Coverage Area, Inter-Canopy PPFD. Every output updates live as you change a parameter.
Outputs depend on the inputs and assumptions shown here. Confirm relevant measurements and local conditions before acting.
Measure the grow footprint in centimetres and convert to square metres (÷10,000), then set the fixture form-factor, count, emission PPF and mount height.
Compute the average canopy PPFD as fixture PPF × count × dim × 0.9 ÷ area, scaled by the inverse-square ratio (30 cm ÷ height)².
Read the uniformity from the fixture form — multi-bar ~95%, quantum board ~85% — and lift the floor by the fixture-count overlap.
Estimate the lower-canopy hand-off with the deliberate inter-canopy fraction (~40% of top) plus any in-canopy tower flux, and the UV share kept inside the UV-A 0–10% / UV-B 0–2% window.
Integrate the daily light integral for your photoperiod, compensating the peak for a sunrise/sunset ramp so the delivered DLI is preserved.
Size the thermal and wiring load: driver waste heat = fixture watts × (1 − eff/100), and cross-check the PPFD by dividing a lux reading by the calibration factor (~650).
Multi-bar LED fixtures hold a roughly 95% uniformity floor across the footprint; a single quantum board concentrates heat and photons into a center hotspot and settles nearer 85% — the difference is exactly the falloff you see at the edges.
The inverse-square law rules coverage: double the mount height and the on-target PPFD quarters. At 30 cm a 1000-µmol/s fixture throws ~900 µmol/m²/s onto a 2 m² canopy, at 60 cm only ~225.
Inter-canopy light is the difference between a top-lit and a volumetrically-lit plant: the lower third sees only about 40% of top-canopy PPFD by Beer-Lambert, and an in-canopy tower is what recovers it.
UV is a finishing tool, not a main source: hold UV-A near 0–10% and UV-B at 0–2% of the photoperiod in flower only, and ramp it up over days — resin, terpenes and pest defense respond, but stress and bleaching do too.
Adding a sunrise/sunset ramp carves about half of peak per ramp, so the controller must raise the peak PPFD to keep the same total DLI — the compensation arm returns exactly that peak and its percent increase.
Uniformity below 80% is a yield tax: hotspots burn the center while edges stretch. Raise the fixture count, lower the mount, or spread the boards before adding raw photon power.
This model combines the earlier Bar-led-vs-quantum-board, Inter-canopy-lighting-vertical-towers, Supplemental-uv-light-grow-lights, Grow-light-dimming-curves-sunrise-sunset, Quantum-par-meter-vs-app, Led-grow-light-driver-heat-management models.
Bar LED spreads the emitters into long, even strips, so a multi-bar fixture holds a uniformity floor of roughly 95% of peak across the footprint — the photons land flat from corner to corner. A quantum board concentrates its diodes into a compact panel, creating a center hotspot and a falling edge, settling near 85% uniformity. That 10-percent gap is the coverage tax: bars win on even spread to the edges, boards win on cost per photon and simplicity in a small reflective tent.
Average PPFD is the fixture photon flux over the carpet: fixture PPF × count × dim × 0.9 ÷ footprint, then scaled by the inverse-square ratio of the reference height to your mount height, (30 ÷ h)². Height matters enormously because light falls off as the square of distance — double the mount and the on-target PPFD quarters. A 1000-µmol/s fixture at 30 cm over 2 m² lands near 900 µmol/m²/s, but at 60 cm roughly 225. That height is the single fastest dial on coverage.
By the Beer-Lambert attenuation model, light decays exponentially through leaf layers with an extinction coefficient near k = 0.6, so the lower third of a dense canopy receives only about 40% of the PPFD at the top. An inter-canopy or tower fixture placed among that canopy adds its own flux directly to the lower leaves — the engine models it as ~40% of top as the baseline hand-off plus the tower boost — which is how vertical and tiered grow systems salvage the bottom buds a top-only light starves.
Supplemental UV is a flower-phase finisher, not a grow-phase source. Keep UV-A near 0–10% of the photoperiod and UV-B at 0–2%, and ramp the on-time up over days rather than switching it on cold. In that window, UV drives resin, terpenes and pest defense responses; beyond it you invite bleaching, curling and crispy margins. The engine reports the UV share as a PPFD arm so you can see exactly how much of the canopy dose is ultraviolet.
A sunrise/sunset ramp means the fixture spends time below peak, so to keep the same total photons in the day — the same DLI — the peak must rise. Each ramp averages about 50% of peak over its duration, so the compensation is flat PPFD × full photoperiod ÷ (photoperiod − 0.5 × combined ramp time). The engine returns that required peak and its percent increase over your flat target, so the gentle dawn is paid for by a slightly higher midday instead of a lost DLI.
A driver turns the fraction (1 − efficiency) of its input power into rejected heat that your cooling must carry. Multiply fixture watts by (1 − eff/100) for the waste watts, then factor 3.41214 to get BTU/h. A 500 W fixture at 90% efficiency rejects 50 W of heat a day — and that number is lower when the mount is higher and the dim is lower. The same arm gives the lux÷factor PAR-meter calibration so you can verify the PPFD a phone reading implies.