Dose the reservoir without guessing. Enter the reservoir volume, the EC target and the pump's rated flow — the engine derates that rating through calibration factor, efficiency, viscosity, temperature and pulsation down to the actual mL/min, converts your run time into the exact volume dosed and EC rise, then returns the pump run that hits the EC target plus the micro-pulse schedule that stays inside a 0.05 mS dead band. Calibration offset, efficiency loss, cost per dose and a green—yellow—red pump-health band close the loop so worn tubing shows up before it drifts your feed.
Flow, volume and losses stack left-to-right; the dashed arc is the stroke the calibration offset trims. Net run-time holds in the centre.
12 parameters · live recalculation on every change
This is a deterministic model: the same inputs always produce the same outputs, calculated entirely in your browser with nothing sent to any server. It is a planning aid — not a quote, not a dosing instruction, and not a yield forecast. Treat every line as a working estimate and validate it against your own prices and measurements.
It models one system: Dose the reservoir without guessing. Enter the reservoir volume, the EC target and the pump's rated flow — the engine derates that rating through calibration factor, efficiency, viscosity, temperature and pulsation down to the actual mL/min, converts your run time into the exact volume dosed and EC rise, then returns the pump run that hits the EC target plus the micro-pulse schedule that stays inside a 0.05 mS dead band. Calibration offset, efficiency loss, cost per dose and a green—yellow—red pump-health band close the loop so worn tubing shows up before it drifts your feed.
The engine computes 10 outputs from your 12 inputs. The headline number is Dosing Time Needed (sec), alongside Actual Flow Rate, Volume Dosed, EC Rise / Dose. Every output updates live as you change a parameter.
Outputs depend on the inputs and assumptions shown here. Confirm relevant measurements and local conditions before acting.
Derate the rated flow: Q_actual = Q_rated × calibration × efficiency/100 × viscosity × temperature / pulsation.
Convert the entered run time: volume dosed = Q_actual × time/60, with the reservoir in mL down below.
Turn that volume into an EC rise: ΔEC = volume dosed ÷ reservoir(mL) × concentration × 2 — the A/B parts counted once each.
Invert the EC formula for time: t = EC target × reservoir(mL) ÷ (Q/60 × concentration × 2) — the pump run that actually lands the target.
Close the calibration loop: offset = rated − actual flow, efficiency loss = 100 − efficiency, and cost = volume dosed ÷ 1000 × stock price.
Read the pump-health band off efficiency and line pressure — green >85%, yellow 70–85%, red below 70% or over 20 psi — then split the run into micro-pulses sized to stay inside the 0.05 mS dead band.
Calibrate flow with a real timed catch — 60 seconds into a graduated cylinder gives mL/min directly, and the pump-calibration blueprint re-tests on a schedule because peristaltic rollers drift as tubing wears.
Dose to net reservoir volume, not the stamped tank: the archived reservoir-volume engine tied every EC shift to the water actually present.
EC rise scales off net volume in milliliters — on defaults, one 60-second run at 90 mL/min actual adds 90 mL to 200 L and moves EC by just 0.0009 mS; reaching the full 1.8 target needs a ~33 h run or a far stronger stock.
The ×2 is structural for A/B loops: two stock bottles feed most peristaltic setups, so the dose is counted once per part. Single-bottle concentrates should halve the concentration input.
Pulsation dampening smooths the hammer but costs throughput — the engine divides actual flow by the dampening factor, which is why a 1.5 dampener on a 10× stock still pays for itself in line life.
Back pressure above 20 psi is a hard red regardless of efficiency: the archive's accumulator sizing treated over-pressure as a failure mode, and so does this band.
This model combines the earlier Dosing-pump-calculator, Peristaltic-pump-calibration, Nutrient-dosing-timer models.
Time a calibrated catch: run the pump for exactly 60 seconds into a graduated cylinder; the mL you collect equals the flow in mL/min. Enter that as the calibration factor (measured ÷ rated) — a 95 mL catch on a 100 mL/min pump is a 0.95 factor — and set the pump-health terms. This engine then shows the calibration offset (rated − actual), so a head that drifted from 100 to 90 mL/min flags the 10 mL/min gap before it under-feeds the crop. Re-test on a schedule, because peristaltic rollers drift as tubing wears.
A peristaltic pump flow rate calculator turns rated output into real delivery: Q_actual = Q_rated × calibration × efficiency/100 × viscosity × temperature ÷ pulsation dampening. That actual mL/min is what volume dosed = Q_actual × time/60 multiplies out, and it is the honest number behind EC rise and dosing time. The archived pump-flow engine derated rated flow for friction, lift and fittings; this arm derates for the pump-health terms a peristaltic head actually sees — so the flow rate you read is what lands in the reservoir, not what the label claims.
t = EC target × reservoir(mL) ÷ ((Q_actual/60) × concentration × 2). On the defaults (200 L, 1.8 EC, 90 mL/min actual, 1× stock) each 60-second run adds only 0.0009 mS and the full target needs roughly a 33-hour run — that is the truth the formulas expose: micro-flow pumps top up a maintained EC, they do not build one. Either raise the concentration to 10× (drops the run ~10×) or read the time as "pump X s per interval" once the target is already held.
A dosing timer without a calibrator doses at rated flow, and the drift is invisible until the crop moans. Run the timed-catch test: if your 100 mL/min rating delivers 90, the timer is short-dosing every cycle by exactly that offset. This tool splits the calculated run into micro-pulses that never overshoot a 0.05 mS dead band — the same pulse discipline the EC-controller blueprint used — and adds a 120-second mixing settle so the next reading is never stale. Recalibrate the flow and the timer follows automatically.
Efficiency loss = 100 − efficiency, and it is the visible symptom of roller wear, head height and line losses. At 90% efficiency the loss line reads 10% and the pump-health band stays green; at 65% (35% loss) the band goes red and this engine halts the schedule. Efficiency enters the flow formula directly, so a head that lost 10% also needs 11% longer to hit the same dose, and the calibration offset line shows the exact mL/min gap — replace the tubing or rollers and the loss line drops back toward the rated flow.
The archived method is the only one that counts: catch the output for 60 seconds in a graduated cylinder, and the collected mL is the flow in mL/min — no math, no rounding. From there this engine computes actual flow by derating that measurement through calibration, efficiency, viscosity, temperature and pulsation dampening, then converts it: volume dosed = flow × time/60, cost per dose = volume/1000 × stock price, and the dosing time = EC target × reservoir ÷ (flow/60 × concentration × 2). Always recalibrate at working temperature and pressure, because cold stock and a long line both shrink the real mL/min.