Skip to content
Done
NUTRIENT SOLUTIONS 4 MIN READ
Plant Care Nutrient Solutions FIELD GUIDE

CF to EC Conversion for UK Growers

CF to EC is a straight divide by 10: the Commonwealth meter multiplies conductivity by 10, so 1.8 mS/cm reads CF 18 and 1,800 µS/cm.

Shoyeb avatar
Founder & Principal Agronomist
SEPTEMBER 2026
•
Updated SEPTEMBER 2026
•
4 MIN READ
CF to EC Conversion for UK Growers
Sep 18, 2026 Plant Care Hub

CF to EC is a straight divide by 10: the Commonwealth meter multiplies conductivity by 10, so 1.8 mS/cm reads CF 18 and 1,800 µS/cm. Reverse the math — CF ÷ 10 = EC in mS/cm — and a UK pen reading CF 24 is feeding 2.4 mS/cm the moment you convert it. The same converter reconciles PPM on the 500, 640 and 700 scales, so a chart printed in mS/cm, CF or PPM finally lands in one language before you mix.

Plant Care ~4 min read · 983 words
One of 54 guides in Plant Care
…Punch in EC and it returns PPM on the 50
…A 1.8 mS/cm solution reads 900 ppm on th
…EC drifts with solution temperature (~2%
…Calibrate in 1413 µS/cm buffer and let t

Key takeaways

  • Punch in EC and it returns PPM on the 500, 640 and 700 scales, plus CF and µS/cm, so any meter and any nutrient chart finally agree.
  • A 1.8 mS/cm solution reads 900 ppm on the 500 scale, 1260 ppm on the 700 scale, and both are correct.
  • EC drifts with solution temperature (~2%/°C).
  • Calibrate in 1413 µS/cm buffer and let the reservoir settle before judging a feed.

How EC / PPM / CF Converter Hub Helps You Master This

  1. Enter the meter reading as EC in mS/cm — the only number you should actually trust from a conductivity pen.
  2. Select the TDS scale printed on your meter: 500 NaCl, 640 KCl or 700 (USA 442). The hub converts all three every time.
  3. Read PPM on your chosen scale plus CF and µS/cm simultaneously so any two pieces of gear can be reconciled.
  4. Compare any two nutrient formulas element-by-element at the same EC to see where one pulls ahead.
  5. For pH, enter current and target pH plus tank volume; the hub suggests the pH Down / pH Up dose for the medium.
  6. Retest 30 minutes after any pH or feed change — the dose is a starting point, never the final word.

The Formula Behind the Result

  • TDS on the USA 442 scale → text{PPM}_{700} = text{EC} ,(text{mS/cm}) times 700
  • NaCl scale — typical of £/American hand-held meters → text{PPM}_{500} = text{EC} times 500
  • EC Factor — the Commonwealth grower scale → text{CF} = text{EC} times 10
  • Conductivity without the milli prefix → text{µS/cm} = text{mS/cm} times 1000
  • pH up/down dose for the tank volume and buffering factor → text{mL} = V,(text{L}) times |Delta pH| times k_{medium}
  • Elemental delta between two formulas at the running EC → Delta e_{i} = k_{i}^{A},text{EC} - k_{i}^{B},text{EC}

Target Ranges: What the Numbers Should Be

  • PPM is a calculation the meter makes, not a physical measurement. Only EC is truly measured; the multiplier is a style choice your meter’s firmware baked in.
  • Always match the scale to your nutrient charts. A 1.8 mS/cm solution reads 900 ppm on the 500 scale, 1260 ppm on the 700 scale, and both are correct.
  • EC drifts with solution temperature (~2%/°C). Calibrate in 1413 µS/cm buffer and let the reservoir settle before judging a feed.
  • pH Down liquid should be diluted 1:10 before dosing small tanks, and always distributed around the reservoir, never dumped in one spot.

Use the free Hydroponic System Selector Quiz — Kratky, NFT & Vertical Tower Blueprint to run the numbers on your own setup.

Use the free Reservoir Change Timer — EC Drift & Flush Schedule Blueprint to run the numbers on your own setup.

Use the free Nutrient Lab Pro — Elemental PPM Formulator to run the numbers on your own setup.

Compare every free calculator side-by-side on the MistCulture tools hub — each one keeps your workspace in sync.

Related guides

Worked example: CF 18 and CF 24 converted to EC and µS/cm

A UK grower’s pen reads CF 18 while the feed chart is written in mS/cm. Convert with CF ÷ 10: 18 ÷ 10 = 1.8 mS/cm, or 1.8 × 1000 = 1,800 µS/cm on the conductivity scale. A meter reading CF 24 means the tank is at 24 ÷ 10 = 2.4 mS/cm — a fruiting-strength feed roughly a third stronger than the 1.8 mS/cm vegetative baseline, and the comparison only makes sense after the conversion. Reversed, EC 2.4 mS/cm on a chart reads as CF 24 on the pen (2.4 × 10). CF never needs a scale debate the way PPM does — it is EC times 10, full stop — so the only mixing risk is a chart that quotes PPM on the 500, 640 or 700 scale without saying which, or a temperature swing shifting the reading ~2% per °C.

  • CF 18 = 1.8 mS/cm = 1,800 µS/cm (CF ÷ 10).
  • CF 24 = 2.4 mS/cm — fruiting-strength vs 1.8 mS/cm vegetative.
  • EC 2.4 mS/cm reads CF 24 on the pen (EC × 10).
  • CF is EC × 10 with no scale split; PPM requires the scale named.

Frequently Asked Questions

References & Science

Frequently asked questions

How do I convert CF to EC on a UK meter?

CF to EC is a straight divide by 10: a pen reading CF 18 means 1.8 mS/cm, and CF 24 means 2.4 mS/cm. For µS/cm multiply the EC by 1,000 — 1.8 mS/cm is 1,800 µS/cm. There is no scale ambiguity because CF is always EC × 10.

What is the biggest mistake UK growers make with CF readings?

Treating a CF reading and a PPM chart as the same number. CF is EC × 10, but PPM varies by meter scale — 500, 640 or 700 — so a 1.8 mS/cm solution is CF 18 yet reads anywhere from 900 ppm to 1,260 ppm. Convert CF to mS/cm first, then to the PPM scale the chart uses.

Which tool helps me convert CF to EC?

The EC / PPM / CF converter on this page takes a single conductivity input and returns CF, µS/cm and all three PPM scales, so a chart printed in any unit can be checked against the pen before you mix. Calibrate in 1413 µS/cm buffer and let the tank settle first.

References

  • Hoagland, D. R. & Arnon, D. I. (1950) — The Water-Culture Method for Growing Plants Without Soil
  • Sonnenveld, C. & Voogt, W. — Plant Nutrition of Greenhouse Crops, Springer
  • Resh, H. M. — Hydroponic Food Production (7th ed.), CRC Press

Related resources

Shoyeb avatar

Shoyeb

Founder & Principal Agronomist @ MistCulture Lab

Founder and editor-in-chief of MistCulture. Shoyeb built the site to give growers honest, engineering-grade hydroponic advice without the hype. He writes the cornerstone guides on systems, troubleshooting, and growing fundamentals, and oversees every article published on the site.

Explore canonical archive

More From the Plant Care Hub

Computational engines

Agronomic Engines Mentioned in This Guide

Hydraulics

Hydroponic System Selector Quiz — Kratky, NFT & Vertical Tower Blueprint

The systems-decision blueprint for a hydroponic grow. Enter the floor area, build budget, your experience level, the crop you want and the…

Launch Full Engine →
Water Chemistry

Reservoir Change Timer — EC Drift & Flush Schedule Blueprint

A hydroponic flush timer that reads your log like a journal: EC current = 1.8 + drift × days + salt term,…

Launch Full Engine →
Nutrients

Nutrient Lab Pro — Elemental PPM Formulator

The elemental PPM formulator. Feed in reservoir volume, target EC and source-water PPM and it returns the real NPK, Ca, Mg and…

Launch Full Engine →
Nutrients

Nutrient Antagonism Lockout Predictor — Mulder Matrix Solver

8x8 Mulder matrix solver. Enter feed ppm, EC, pH and temperature and the engine returns per-ion antagonism, uptake ratios, lockout risk, the…

Launch Full Engine →
Community

Start the discussion

No comments yet — your grow-room experience is the first data point.

Leave a comment

Plain-text replies only. Experience and measured readings beat theory here.

Field Protocol Dispatch | Vol. 2026