Plant Care
- • Climate Control & VPD16
- • Disease & Pest Management14
- • Nutrient Solutions & EC34
- • Plant Health Monitoring7
12 parameters · live recalculation on every change
One bridge at a time: what the water can hold, what the system takes back, and the DO your roots actually see.
Running total after each term — the final net matches the headline reading in the result card, kept in sync live.
This is a deterministic model: the same inputs always produce the same outputs, calculated entirely in your browser with nothing sent to any server. It is a planning aid — not a quote, not a dosing instruction, and not a yield forecast. Treat every line as a working estimate and validate it against your own prices and measurements.
It models one system: A dissolved oxygen calculator that starts from the saturation ceiling your water can actually hold — the Benson & Krause 1984 temperature and salinity polynomial (9.1 mg/L at 20 °C, 7.5 at 30 °C, 11.3 at 10 °C, sea level, 0 ppt) corrected for altitude and barometric pressure — then applies your aeration type efficiency (air stone 70%, venturi 90%, waterfall 50%, diffuser 75%) scaled by bubble size, air flow and stirring, subtracts root respiration and organic load, and closes the DO picture in a green—yellow—red safety band around the 6.0 mg/L root-zone survival line.
The engine computes 10 outputs from your 12 inputs. The headline number is Dissolved Oxygen (mg/L), alongside Saturation Ceiling, Saturation, Aeration Efficiency. Every output updates live as you change a parameter.
Outputs depend on the inputs and assumptions shown here. Confirm relevant measurements and local conditions before acting.
Saturation anchors to remember: 14.6 mg/L at 0 °C, 9.1 at 20 °C, 7.5 at 30 °C, all sea level and 0 ppt — the Benson & Krause family of the archived water-temp-do-risk engine.
Salinity 35 ppt loses roughly 20% of the ceiling; altitude costs about 12% per 1000 m ascent.
Aeration device efficiency locked at air stone 70%, venturi 90%, waterfall 50%, diffuser 75% — the venturi wins by shearing the surface, which is why it beats any air stone.
Bubble size scales the base: 0.5 mm fine stone 1.3×, 2 mm baseline 1.0×, 5 mm coarse 0.7×.
Consumption: root respiration 0.5 mg/L/h baseline × factor, plus 0.1 mg/L/h for every 50 ppm of organic load.
Safety bands: > 6 mg/L GREEN, 4–6 YELLOW (stress), 26 °C, consumption > 3 mg/L/h, or saturation < 60%.
This model combines the earlier Dissolved-oxygen-calculator, Oxygen-saturation-calculator, Aeration-calculator models.
The dissolved oxygen calculator computes your real root-zone DO in mg/L by multiplying the temperature-and-salinity saturation ceiling (9.1 mg/L at 20 °C, sea level) by your aeration device efficiency — air stone 70%, venturi 90%, waterfall 50%, diffuser 75% — scaled for bubble size, airflow and stirring, then subtracting root respiration and organic load. The result is benchmarked against the 6 mg/L survival line and 4 mg/L death line in the safety band.
Oxygen saturation in water is 14.6 mg/L at 0 °C, 9.1 at 20 °C, and 7.5 at 30 °C at sea level and zero salinity. The oxygen saturation calculator applies the Benson & Krause 1984 polynomial to your temperature and salinity, corrects for altitude and barometric pressure, and reports both the saturation ceiling and the saturation percentage your aerator actually reaches.
Hydroponic roots want 6 mg/L or more of dissolved oxygen — 7–9 mg/L is the ideal band. Between 4 and 6 mg/L roots are stressed and Pythium risk climbs; below 4 mg/L they begin dying within hours. The DO calculator flags each tier in its green-yellow-red safety band.
The aeration calculator scales device transfer efficiency by bubble size, airflow, and stirring: air stone 70%, venturi 90%, waterfall 50%, diffuser 75%, with fine 0.5 mm bubbles worth 1.3× and coarse 5 mm bubbles 0.7×. It converts your aeration setup into the real mg/L you deliver, not the theoretical ceiling.
DO saturation falls with temperature: 14.6 mg/L at 0 °C, 10.9 at 15 °C, 9.1 at 20 °C, 8.2 at 25 °C, and 7.5 at 30 °C at sea level and zero salinity. This is exactly why warm reservoirs read low even with big aerators — the ceiling itself shrinks.
Increase dissolved oxygen fastest with a venturi or waterfall that breaks the water surface (90% transfer) rather than bigger air stones; switch to fine 0.5 mm bubbles (1.3×), raise airflow and stirring, and drop water temperature — each degree under 26 °C raises the saturation ceiling the aeration has left to fill.