Climate Controller & HVAC Sizer — VPD, Dehumidifier & CO2 Blueprint

The climate blueprint for the sealed grow room. Room volume, target temperature and humidity, and the lights-on/off swing feed the VPD, dehumidifier, HVAC and CO2 arms. VPD runs the archived Tetens saturation curve with the leaf pegged −2 °C under LED; the dehumidifier arm sizes transpiration at 0.5 L per plant per day into pints; the HVAC arm prices sensible cooling at a 23.5 W/m³ design factor by envelope (poor 1.5 → excellent 0.5) and air change, converted to BTU at 3.412; the CO2 arm fills to your target ppm at 1.8e-6 kg per m³ per ppm with the leak added to the sustained daily dose. Outputs: HVAC sizing in BTU/h, dehumidifier pints, CO2 kg/day, leaf VPD, CFM exchange, cooling and heating watts, the $/day run cost, and the green—yellow—red safety read.

Climate load stack

live
Cooling load 3525
Heating load 2820
Dehumidifier 20
CO2 injection 0.14
Air exchange 29.4

Each segment is one load family; the required HVAC size holds in the centre as the sum you have to provision.

Inputs

10 parameters · live recalculation on every change

M³
10m³ 100m³ default 1000m³
°C
15°C 25°C default 35°C
%
30% 60% default 90%
°C
20°C 28°C default 40°C
°C
10°C 20°C default 30°C
Deterministic model 10 inputs · 10 outputs Runs 100% in your browser

This is a deterministic model: the same inputs always produce the same outputs, calculated entirely in your browser with nothing sent to any server. It is a planning aid — not a quote, not a dosing instruction, and not a yield forecast. Treat every line as a working estimate and validate it against your own prices and measurements.

It models one system: The climate blueprint for the sealed grow room. Room volume, target temperature and humidity, and the lights-on/off swing feed the VPD, dehumidifier, HVAC and CO2 arms. VPD runs the archived Tetens saturation curve with the leaf pegged −2 °C under LED; the dehumidifier arm sizes transpiration at 0.5 L per plant per day into pints; the HVAC arm prices sensible cooling at a 23.5 W/m³ design factor by envelope (poor 1.5 → excellent 0.5) and air change, converted to BTU at 3.412; the CO2 arm fills to your target ppm at 1.8e-6 kg per m³ per ppm with the leak added to the sustained daily dose. Outputs: HVAC sizing in BTU/h, dehumidifier pints, CO2 kg/day, leaf VPD, CFM exchange, cooling and heating watts, the $/day run cost, and the green—yellow—red safety read.

What the Climate Controller & HVAC Sizer — VPD, Dehumidifier & CO2 Blueprint returns

The engine computes 10 outputs from your 10 inputs. The headline number is HVAC Sizing (BTU/h), alongside Dehumidifier, CO2 Feed, Leaf VPD. Every output updates live as you change a parameter.

What it does not do

Outputs depend on the inputs and assumptions shown here. Confirm relevant measurements and local conditions before acting.

Save to Grow Room

Choose a workspace, then commit the current inputs and result to it. Stored only in your browser.

Snapshot—
Saved at:—
✓ Saved to your grow-room workspace