ⓘ Basis of calculation How it’s computed
1

Measure air temperature, relative humidity, growth stage, altitude and leaf temperature offset.

2

Convert temperature into degrees Celsius if working in Fahrenheit.

3

Compute saturation vapour pressure of the air using the Tetens equation: SVP = 0.6108 · e^(17.27T / (T + 237.3)).

4

Compute leaf saturation vapour pressure using the leaf temperature (air temperature + leaf offset).

5

Compute actual vapour pressure: AVP = SVP(air) × RH / 100.

6

True leaf VPD = SVP(leaf) − AVP; apply the altitude pressure factor, then classify against the growth-stage target.

Live output

True Leaf VPD

Live
0.75 kPa

True Leaf VPD

Below Target · reduce RH to lift VPD toward 0.8–1.2 kPa
Air VPD 1.11 kPa
Sat. Vapour Pressure (Air) 3.17 kPa
Sat. Vapour Pressure (Leaf) 2.81 kPa
Actual Vapour Pressure 2.06 kPa
Mode standard Active profile
0.4 spore risk 0.8–1.2 target 1.6+ closure
VPD & Leaf Temperature Engine Powered by MistCulture Full VPD & Leaf Temperature Engine · All tools